The BLAST-E drives conceived for most different industrial applications and allow a continuous speed control of brushless and asynchronous from 0 to a max. value.
They are extremely compact, reliable and cost attractive as well as easy to use; they can find application in all application fields for sinusoidal brushless servomotors and asynchronous motors.
The DSP control system allows high programming flexibility.
The PWM modulation and the low-loss semi-conductive devices grant the drive's high efficiency.
Operating data |
PWM frequency | 1; 1,5; 2; 4; 8; 12kHz (min. 4kHZ for SB and SB+Posi) |
Resolver input | supply frequency 4kHz, resolution 12bit/rev. |
Configuration parameters | nominal current, motor current at the nominal voltage without load, nominal frequency, nominal speed, nominal voltage, nominal power, nominal cosj. |
Frequency control | 0 - 1000Hz (resolution 0,2Hz) |
Torque control | from +/- 10% to +/-20% of the nominal motor value |
Acc./decel. | 0,3 do 40 000 sec. |
Ramp type | trapezoidal and physiological, "S" from |
Current control | up to 200% of the nominal current |
Overload | 150% of the nom. current 1' every 10' 200% of the nom currrent 10'' every 10' |
Frequency derating | 1 - automatic 2 - manual with current reduction |
Frequency control input | 0 - 10 kHz |
Analog control input | +/- 10V, 4 - 20mA resolution 12 bit |
Configuratable commands | 24Vcc input2 |
Alarm singnalling | ralay contact 0-110V ac - AC1 |
PID control | on correction signal from the main reference |
Configurable signalling | ralay contact 0-110V ac - AC1 |
Auxiliary Output, to configurate through dip switch | analog 0-10V/0-10kHz frequency resolution 8 bit + sign |
Protections | Current limit (only SB ) Motor protection (limit or I2t) 0verload (inverter only) Undervoltage(<400V DC) Overvoltage(>800V DC) Thermal protection drive with displayed temp. Short circuit between phases and to ground Brake resistor thermal protection Congruence error (for feedback only) |
Basic programming | Digital programming through 4 keys (on optional keypad) |
Serial port | DEVICE NET (no optocoupled) |
Net connection with optional board | CAN-BUS(DeviceNet), PROFIBUS, SERCOS, RS485(modbus), RS232 for PC connection |
Dynamic brake | built -in up to do 22kW |
Brzdný rezistor | built -in up to 11kW |
Pattern lines |
Size A | Three phase power |
Output current [A] |
Delivery converters 400V [kW] |
Maximum Output current [A] |
Apparent Delivery converters [kVA] |
BLAST-E 0007 BAH | 380V -15% 480V +5% 45/65Hz |
2,5 | 0,75 | 5 | 1,7 |
BLAST-E 0011 BAH | 3,5 | 1,0 | 7 | 2,4 | |
BLAST-E 0015 BAH | 4,8 | 1,5 | 10 | 3,3 | |
BLAST-E 0022 BAH | 6,0 | 2,2 | 12 | 4,2 | |
BLAST-E 0037 BAH | 9,5 | 3,7 | 19 | 6,5 | |
BLAST-E 0055 BAH | 13 | 5,5 | 26 | 9 |
Size B | Three phase power |
Output current [A] |
Delivery converters 400V [kW] |
Maximum Output current [A] |
Apparent Delivery converters [kVA] |
BLAST-E 0075 BBH | 380V -15% 480V +5% 45/65Hz |
16,5 | 7,5 | 33 | 11,4 |
BLAST-E 0110 BBH | 25 | 11 | 50 | 17,3 | |
BLAST-E 0150 BBH | 31 | 15 | 62 | 22 | |
BLAST-E 0185 BBH | 39 | 18,5 | 78 | 27 | |
BLAST-E 0220 BBH | 45 | 22 | 90 | 32 |
Size C | Three phase power |
Output current [A] |
Delivery converters 400V [kW] |
Maximum Output current [A] |
Apparent Delivery converters [kVA] |
BLAST-E 0300 BCH | 380V -15% 480V +5% 45/65Hz |
62 | 30 | 125 | 43 |
BLAST-E 0370 BCH | 76 | 37 | 152 | 53 | |
BLAST-E 0450 BCH | 90 | 45 | 180 | 63 |
Size D | Three phase power |
Output current [A] |
Delivery converters 400V [kW] |
Maximum Output current [A] |
Apparent Delivery converters [kVA] |
BLAST-E 0550 BDH | 380V -15% 480V +5% 45/65Hz |
112 | 55 | 224 | 78 |
BLAST-E 0600 BDH | 120 | 60 | 240 | 83 | |
BLAST-E 0750 BDH | 150 | 75 | 300 | 104 |
Size E | Three phase power |
Output current [A] |
Delivery converters 400V [kW] |
Maximum Output current [A] |
Apparent Delivery converters [kVA] |
BLAST-E 0900 BEH | 380V -15% 480V +5% 45/65Hz |
180 | 90 | 360 | 126 |
BLAST-E 1100 BEH | 220 | 110 | 440 | 152 | |
BLAST-E 1320 BEH | 260 | 132 | 520 | 180 | |
BLAST-E 1600 BEH | 320 | 160 | 640 | 221 |
Equipment |
Order code | Specification |
BLAST-E OPT 0010 | 7 segment dssplay and keyboard (supplied standard) |
BLAST-E OPT 0030 | card RS 232 |
BLAST-E OPT 0031 | card RS 232 + kabel L=1,5m |
BLAST-E OPT 0040 | card RS 485 |
BLAST-E OPT 0041 | card RS 485 + kabel L=1,5m |
BLAST-E OPT 0050 | card CAN BUS s DeviceNet |
BLAST-E OPT 0060 | card PROFIBUS DP |
BLAST-E OPT 0110 | card Back-UP 24V |
Programme XBLAST |
XBLAST program is supplied free of charge together with the converter. This program is used for programming the converter, storing the set-up values on a computer hard drive, and recording the measured values of the current, speed, position, input and output signals using the “SCOPE” function. This program also regulates the operation of the drive. For more information, refer to the Instruction and User Manual for converter B